Product Code: 112283056

Address:

Shandong,China

Main Products:

Education equipment,Teaching Equipment,science laboratory equipment,mechatronics training Equipment,elevator trainer,position control trainer,robot trainer,Industrial Automation Training set,PLC Training set,Inverter Training set,Pneumatic and hydrau

Contact Info.
Power system relay protection laboratory training equipment
  • FOB Price
    US $ 100.00 / Set(s)
  • Min. Order
    1 Set(s)
  • Payment Terms
    -- --
  • Port
    Qingdao
  • Delivery Time
    30 days after payment
  • Place of Origin:
    Shandong China (Mainl...
  • Brand Name:
    Xingke
  • Model Number:
    XK-DB1
  • Training equ...:
    Power system relay pr...
  • Scientific l...:
    Teaching equipment
  • Education eq...:
    Training equipment
Product Description

XK-DB1 Power system relay protection laboratory bench

 

Product overview

XK-DB1 Power system relay protection laboratory bench is well-designed and manufactured by synthesizing teaching content on relay protection, electrical equipment, automatic device, factory electricity supply, power system microcomputer protection and other professional courses in institutions of higher learning, combining with working practical experience of power plant, substation , factory substation and other departments. The laboratory bench can carry out dozens of experimental training such as relay characteristic, relay protection, relay comprehensive protection, secondary circuit and so on. This device can meet the students learning and doing experiment of the basic functions of power system microcomputer protection, also help students master operating principle, internal structure, basic characteristics, setting debugging and validation of common relay (reclosing relay, differential relay, power directional relay, synchronizing checking relay, induction inverse time overcurrent relay, rectification direction impedance relay, phase meters, switch component, etc.)

Detailed instructions for use and typical project cases are equipped.

 

Technical parameters

1. Input power supply: Three-phase four-wire (or three-phase five-wire), 380V ± 10%, 50HZ
2. Work environment: try to avoid corrosive gases and dust  

    Temperature: -10 °C - +40 °C

    Relative humidity: ≤ 85% (25 °C)

    Elevation: <4000m

3. Leakage Protection Index

   Current: 30mA

   Voltage: < 36V

4. Overall capacity: ≤1KVA

5. Weight: <180 kg
6. Overall dimensions: 1786mm × 720mm × 1600mm

 

Experimental training projects

I. Relay characteristic experimental training
1. Experimental training of electromagnetic voltage relay
2. Experimental training of electromagnetic current relay
3. Experimental training of electromagnetic time relay
4. Experimental training of electromagnetic auxiliary relay
5. Experimental training of auxiliary relay with holding coil
6. Experimental training of auxiliary relay with delayed contact

7. Experimental training of signal relay
8. Experimental training of negative sequence voltage relay
9. Experimental training of shock relay characteristic
10. Experimental training of once reclosing relay characteristic
11. Experimental Training of flash relay

II. Relay protection experimental training

1. Constant time-lag over-current protection experimental training
2. Instantaneous over-current quick-break protection experimental training
3. Inverse time lag over-current protection experimental training
4. 6-10KV line two-stage current protection experimental training
5. 6-10KV line three-stage current protection experimental training
6. Low-voltage interlocking over-current protection experimental training
7. Low voltage starting over-current actions experimental training
8. Compound voltage starting over-current protection experimental training
9. Unilateral power circuit three-phase once reclosing relay experimental training
10. Acceleration before automatic reclosing protection experimental training
11. Acceleration after automatic reclosing protection experimental training
12. Generator over-voltage protection experimental training
13. Bright standby two-way power supply each other input circuit training
14. Dark standby bus tie circuit breaker automatic input circuit training

III. Secondary control circuit experimental training

1. Circuit breaker manually separating brake and switching in experimental training
2. Flasher consisted of flashing relay experimental training
3. Circuit breaker control with lighting monitoring experimental training
4. Circuit breaker control with lighting and sound monitoring experimental training
5. Centre resetting no repetitive action fault signalling device experimental training
6. Centre resetting repetitive action fault audible signal device experimental training

7. Circuit breaker equipped with anti-bouncer lockout control loop experimental training
8. Centre resetting repetitive action anticipating signal device experimental training

9. 6 ~ 10KV busbar voltage measurement and insulation monitoring experimental training
IV. Relay protection comprehensive experimental training

1. Two-stage current protection and acceleration before automatic reclosing experimental training
2. Two-stage current protection and acceleration after automatic reclosing experimental training
3. Low-voltage lockout over-current protection and acceleration before automatic reclosing  experimental training

4. Low-voltage lockout over-current protection and acceleration after automatic reclosing experimental training
 5. Low-voltage starting over-current protection and acceleration before automatic reclosing experimental training
 6. Low-voltage starting over-current protection and acceleration after automatic reclosing experimental training

7. Compound voltage starting over-current protection and acceleration before automatic reclosing experimental training
 8. Composite voltage starting over-current protection and acceleration after automatic reclosing experimental training
 9. Two-way power supply input each and constant time-lag over-current protection experimental training
 10. Two-way power supply input each and current quick-break protection experimental training
 11. Bus tie circuit breaker automatic input and constant time-lag over-current protection experimental training
 12. Bus tie circuit breaker automatic input and current quick-break protection experimental training
V. Microprocessor protection simulation training
1. Current quick-break protection simulated experiment
2. Current quick-break protection with the directional lockout simulated experiment
3. Low-voltage lockout current quick-break protection simulated experiment
4. Current quick-break protection With the constant doubling simulated experiment
5. Timed current quick-break protection simulated experiment
6. Timed current quick-break protection With the directional lockout simulated experiment

7. Low-voltage lockout timed current quick-break protection simulated experiment

8. Timed current quick-break protection with the constant doubling simulated experiment
9. Constant time-lag over-current protection simulated experiment

10. Constant time-lag over-current protection with the directional lockout simulated experiment

11. Low-voltage lockout constant time-lag over-current protection simulated experiment

12. Constant time-lag over-current protection with the constant doubling simulated experiment

13. Inverse time lag over-current protection simulated experiment
14. Negative-sequence current protection simulated experiment
15. Negative-sequence voltage protection simulated experiment
16. Over voltage protection simulated experiment