Item | Performance Characteristics | ||||||||
Operating Temperatuer Range | -40℃~+85℃ | ||||||||
Rated Working Voltage | 10~450V.D C | ||||||||
Nominal capacitance range | 47~47000u F | ||||||||
Capacitance Tolerance | ±20%(25℃,120Hz) | ||||||||
Leakage Current | I≤0.02CV(u A) 5minutes | ||||||||
Dissipation Factor |
(tanδ)
W.V. |
(25℃)
10 |
(120Hz 25℃)
16~25 |
35~63 | 80~100 | 160~250 | 300~450 | ||
C(uF) | 22000~47000 | 4700~10000 | 22000~47000 | 2200~6800 | 10000~22000 | 1000~6800 | 100~1000 | 22~470 | |
(tanδ) | 0.50 | 0.35 | 0.40 | 0.25 | 0.30 | 0.2 | 0.2 | 0.2 | |
Temperature characteristics (120Hz) | W.V. | 10~160 | 200~450 | ||||||
Z-25℃/+20℃ | 4 | 7 | |||||||
Z-40℃/+20℃ | |||||||||
1is added to every 1000u F increase over 1000u F | |||||||||
Load life | After applying rated voltage with specified ripple current for 1000 hours at+85℃ and then resumed 16 hours: | ||||||||
Capacitance change:Within ±20% of the lnitial measured value | |||||||||
Leakage current:Not more than the initial specified value | |||||||||
Dissipation factor;Not more than 150% of the initial specified value | |||||||||
Shelf Life | After storage for 500 hours at +85℃ then resumed 16 hours: | ||||||||
Capacitance change: Within ±20% of the lnitial measured value | |||||||||
Leakage current:Not more than 200% of the initial specified value | |||||||||
Dissipation factor;Not more than 120% of the initial specified value | |||||||||